Marvell SEI (System Error Interrupt) Controller
|
|
-----------------------------------------------
|
|
|
|
Marvell SEI (System Error Interrupt) controller is an interrupt
|
|
aggregator. It receives interrupts from several sources and aggregates
|
|
them to a single interrupt line (an SPI) on the parent interrupt
|
|
controller.
|
|
|
|
This interrupt controller can handle up to 64 SEIs, a set comes from the
|
|
AP and is wired while a second set comes from the CPs by the mean of
|
|
MSIs.
|
|
|
|
Required properties:
|
|
|
|
- compatible: should be one of:
|
|
* "marvell,ap806-sei"
|
|
- reg: SEI registers location and length.
|
|
- interrupts: identifies the parent IRQ that will be triggered.
|
|
- #interrupt-cells: number of cells to define an SEI wired interrupt
|
|
coming from the AP, should be 1. The cell is the IRQ
|
|
number.
|
|
- interrupt-controller: identifies the node as an interrupt controller
|
|
for AP interrupts.
|
|
- msi-controller: identifies the node as an MSI controller for the CPs
|
|
interrupts.
|
|
|
|
Example:
|
|
|
|
sei: interrupt-controller@3f0200 {
|
|
compatible = "marvell,ap806-sei";
|
|
reg = <0x3f0200 0x40>;
|
|
interrupts = <GIC_SPI 0 IRQ_TYPE_LEVEL_HIGH>;
|
|
#interrupt-cells = <1>;
|
|
interrupt-controller;
|
|
msi-controller;
|
|
};
|