* Dialog DA9062/61 TJUNC Thermal Module
|
||
|
|
||
|
This module is part of the DA9061/DA9062. For more details about entire
|
||
|
DA9062 and DA9061 chips see Documentation/devicetree/bindings/mfd/da9062.txt
|
||
|
|
||
|
Junction temperature thermal module uses an interrupt signal to identify
|
||
|
high THERMAL_TRIP_HOT temperatures for the PMIC device.
|
||
|
|
||
|
Required properties:
|
||
|
|
||
|
- compatible: should be one of the following valid compatible string lines:
|
||
|
"dlg,da9061-thermal", "dlg,da9062-thermal"
|
||
|
"dlg,da9062-thermal"
|
||
|
|
||
|
Optional properties:
|
||
|
|
||
|
- polling-delay-passive : Specify the polling period, measured in
|
||
|
milliseconds, between thermal zone device update checks.
|
||
|
|
||
|
Example: DA9062
|
||
|
|
||
|
pmic0: da9062@58 {
|
||
|
thermal {
|
||
|
compatible = "dlg,da9062-thermal";
|
||
|
polling-delay-passive = <3000>;
|
||
|
};
|
||
|
};
|
||
|
|
||
|
Example: DA9061 using a fall-back compatible for the DA9062 onkey driver
|
||
|
|
||
|
pmic0: da9061@58 {
|
||
|
thermal {
|
||
|
compatible = "dlg,da9061-thermal", "dlg,da9062-thermal";
|
||
|
polling-delay-passive = <3000>;
|
||
|
};
|
||
|
};
|